Features
- None Available
Specifications
- AC CURRENT (Typ.): 0.6A/115VAC; 0.35A/230VAC
- CURRENT RANGE: 0~5A
- DC VOLTAGE: 5V
- DIMENSION: 99*97*36mm (L*W*H)
- EFFICIENCY(Typ.): 72%/115VAC
- EMI CONDUCTION & RADIATION: Compliance to EN55022 (CISPR22) Class B
- EMS IMMUNITY: Compliance to EN61000-4-2,3,4,5; ENV50204, EN55024, Light industry level, criteria A
- FREQUENCY RANGE: 47 ~ 63Hz
- HARMONIC CURRENT: Compliance to EN61000-3-2,-3
- HOLD TIME (Typ.): 90ms/230VAC, 12ms/115VAC at full load
- INRUSH CURRENT (Typ.): COLD START 13A/115VAC; 25A/230VAC
- ISOLATION RESISTANCE: I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
- LEAKAGE CURRENT: <0.75mA / 240VAC
- LINE REGULATION: ±0.5%
- LOAD REGULATION: ±1.0%
- MTBF: 330.8K hrs min.; MIL-HDBK-217F (25°C)
- OUTPUT VOLTAGE ADJ. RANGE: 4.75 ~ 5.5V
- OVER LOAD PROTECTION: 105 ~ 150% rated output power; Protection type : Hiccup mode, recovers automatically after fault condition is removed.
- OVER VOLTAGE PROTECTION: 5.75V ~ 6.75V; Protection type : Hiccup mode, recovers automatically after fault condition is removed.
- RATED CURRENT: 5A
- RATED POWER: 25W
- RIPPLE & NOISE (max.): 50mVp-p
- SAFETY STANDARDS: UL1012, TUV EN60950-1 Approved
- SETUP, RISE TIME: 300ms, 50ms/230VAC, 800ms, 50ms/115VAC at full load
- STORAGE TEMP., HUMIDITY: -20 ~ +85°C , 10 ~ 95% RH
- TEMP. COEFFICIENT: 0.03%/°C(0 ~ 50°C)
- VIBRATION: 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
- VOLTAGE RANGE: 85 ~ 264VAC; 120 ~ 370VDC
- VOLTAGE TOLERANCE: ±2.0%
- WITHSTAND VOLTAGE: I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
- WORKING HUMIDITY: 20 ~ 90% RH non-condensing
- WORKING TEMP.: -10 ~ +60°C(Refer to output load derating curve)